Brand Name : Fenigal/OEM
Model Number : DXLE
Certification : CCC, CE etc.
Place of Origin : China
MOQ : 12pcs / 1doz.
Price : Negotiate
Payment Terms : T/T, Western Union
Supply Ability : 200,000 pcs/month
Delivery Time : 2~15days
Packaging Details : standard in carton box
Model : DXLE
Pole(s) : 2,4
Volt : 220~240VAC, 380~400VAC
Hz : 50~60Hz
Phase : 1/3
Standard : EN/IEC61008
Rated conditinal short circuit capacity : 6000A
Earth leakage current : 30mA, 100mA, 300mA
Case material : Nylon 66 recylable
Wiring : terminal block, busbar duct etc. IP20B
Electric shock protection : Class II
Mechanical life : 10,000
Electrical life : 4,000
Residual current circuit breaker (without over-current protection) is suitable for the line of AC 50/60Hz,voltage 240V(2pole)/415V(4pole),rated current up to 63A.When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, RCCB will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage.
It can be used as infrequent changeover of the line in normal situation. RCCB is applicable to industrial area, commercial area, tall building and civil house.
It complies with standard IEC/EN61008.1 and GB16916.1
The Residual Current Circuit Breakers (RCCBs) range is commonly used to open a circuit automatically in the case of an earth leakage fault between phase/ neutral and earth, greater or equal to 10, 30, 100, 300 or 500mA.
Newest type RCCB
 
 Application:
 
 1. For protection against risk of fire due to live to earth fault where fault current is insufficient to cause over-current protection device to operate
 
 2. For protection against risk of shock from indirect contact with equipment suffering a live to earth fault.
 
 3. For protection against shock in potentially hazardous environment
 
 4. As supplementary protection against shock from directly touching live parts
 Note: An RCCB must not be used as the sole means of protection against touching live parts
 
 
 Specification:
 
 Rated working voltage: 240/415V
 Rated frequency: 50/60Hz
 Rated working current: 16, 20, 25, 32, 40, 50, 63, 80, 100A
 Rated residual operating current: 0.03, 0.1, 0.03A
 Sensibility: AC Type
|  			 Model NO.   			DXLE RCCB  			Breaking Capacity   			Low Voltage Circuit Breakers  			Operation   			Electric Type  			Speed   			Normal Type Circuit Breaker  			Arc-extinguishing Medium   			Air  			Installation   			Fixed  			Structure   			Conventional Circuit Breaker  			Certification   			CE  			Body Material   			PA66  			The Inside Parts   			IEC Standard Accessaries  			Type   			Circuit Breaker  			Function   			Overcurrent Protection  			Trademark   			Fenigal/OEM  			Specification   			IEC1008, GB16916, BS EN61008  			Origin   			China Wenzhou  			 |  		











| 
                                             | 
                